Acctiva standard

Product information

  • For charging or charge conservation of conventional lead acid, lead calcium/silver batteries, or those of the sealant type (AGM, MF), as well as maintenance-free lead GEL batteries, without disconnecting from the vehicle power supply.
  • Up to a maximum charging current of 20 Amperes
  • Compact design thanks to primary switched mode power electronics
  • Based on Active Inverter Technology

Technical data

Acctiva Standard 12-10 12-20 24-5 24-10 12/24/20
Nominal charging voltage 12 V 12 V 24 V 24 V 12 V/24 V
Charging current 10 AMP 20 AMP 5 AMP 10 AMP 20 AMP
Battery capacity 36-180 Ah 44-300 Ah 10-100 Ah 36-180 Ah 44-300 Ah
Mains voltage 230 V +/- 15 %
Charging characteristic IWUoU IUoU/IU IWUoU IUoU/IU IUoU/IU
Marks of conformity CE
Lenght of charger lead 1,4 m
Mains lead the correct mains lead for the destination country will be supplied
Dimensions (LxWxH in mm) 188x142x70 285x142x70 188x142x70 285x142x70 285x142x70
Weight 1 kg 1,75 kg 1 kg 1,75 kg 2,05 kg
Final charge voltage 13,5-14,4V 13,5-14,4V 27-28,8V 27-28,8V

12V:13,5-14,4V

24V:27-28,8V

Equipment features

Applications

  • Charging mode: Automatic charging with IUoU characteristic
  • Trickle charging: Consumer loads switched on and in use during charging (powering demonstration vehicles in the showroom)
  • Back-up mode: Back-up of vehicle power supplies without integral starter battery, voltage retention when changing the battery.
  • Conservation charging: After charging, automatic switchover to conservation charging

Protective features

  • Electronic reverse polarity protection
  • Thermal overload protection
  • Electronically safe
  • Short-circuit protection